ZT-100 T-Series
ZelenTech ZT-100 Watercut Meters (BS & W, OWM)
Features
- Automatic Temp Comp
- Optional Density Comp
- HART + Modbus available
- PC Interface
Certifications
- ATEX EXD
- GOST EXD
- US/CAN EXD
The ZelenTech T-Series is a new range of insert Watercut Monitors (also known as BS&W, OWD, WFM or Water in Oil Analyzers) developed in-house
The T-Series is primarily designed for insertion into smaller pipes and specifically targeted at Well-Head applications where this type of meters are in common use. The ZT100 T=Series will fit in any 3/4 inch NPT socket previously used for other brands using similar designs.
The T-Series is inserted through a 3/4 inch NPT nipple and complements the I-Series insertion meters that is geared towards large pipes.
The ZelenTech ZT-100 Watercut Monitor determines the percent watercut in an oil emulsion without requiring the physical separation of the fluids. The emulsion stream is continuously monitored for capacitance and converted into percentage of water by the Watercut Monitor logic.
- Inherits functionality and safety from the well proven ZT-100 F, S and I-Series.
- Fully Blow-Out Proof Safe design.
- Up to ANSI Class 600#
- Retractable.
- Retractable under pressure (available soon).
- NEL, ATEX or GOST certifications available.
Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728T-Series General Data
Parameter | Value |
---|
Principle of Operation | High Frequency Digital Capacitance |
Resolution | 0.05% |
Accuracy | 0.05% |
Repeatability | 0.01% Absolute |
Max Water | 100% |
Temp Compensation Range | 0°C – 180°C |
Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728T-Series Specification
Parameter | Value |
---|
Response time | 1 sec |
Sensitivity | 0.01% |
Repeatability | 0.1% |
Output | 4-20mA + HART |
Power Supply | 24VDC (Loop Powered) |
Power Consumption | 0.66W Max |
Temperature (Media) | +150° C (250 with High Temp Option) |
Temperature (Ambient) | +60° C |
Ingress Protection | IP66 / Nema 4X & 7 |
Measurement Range | 0-100% |
Pressure Rating | Up to Class 600# |
Probe entry nozzle sizes | 3/4 inch NPT |
Line Sizes Nominal Sizes | 2 or 3 inch or larger using adapter |
Material (Standard) | 316L (Optional Duplex, Monel or other steels) |
Seals and electrical insulators | PEEK |
Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728Deprecated: strlen(): Passing null to parameter #1 ($string) of type string is deprecated in
/home4/zelentec/public_html/website_e665a57f/site/assets/cache/FileCompiler/site/modules/ProFields/FieldtypeTable/FieldtypeTable.module on line
728T-Series Mechanical Data
Parameter | Value |
---|
Wetted Steel Material | 316L Standard (More exotic materials available) |
Seals | PEEK |
Max. Working Pressure | Up to Class 600# |
Max. Fluid Temperature | 180°C Standard (240°C Optional) |
Max. Ambient Temperature | 65°C |
Process Connection | 3/4 inch NPT or 2 inch flanged adapter |
The ZT-100 is available with a variety of certifications to suit different locations
ETL US/CAN
EXD Class 1, Division 1
ATEX
II 2 GD Ex d IIC T6÷T4 - Ex tD A21 IP 66/67 T85°C ÷ T135°C
GOST
Certified GOST EXD (Russia)
T-Series Configurations and Features
3/4 inch NPT Insertion Model:
- Sits through elbows into 2 inch or 3 inch lines.
- Suits larger pipes using adaptors
- Qucik and simple setup
- Compatible with existing 3/4 inch nozzles made for similar instrument designs
- Compatible with any Piping Specification
Design Features:
- Safe Blow-Out Proof Design
- Low Flow distortion
- 2-wire Loop powered
- Temperature Compensation
- Optional Density Compensation
- Retractable